{"product_id":"blakeslee-rc86-hr-87-in-double-tank-rack-conveyor-dishwasher-heat-recovery-prewash-dual-final-rinse","title":"Blakeslee RC86 HR 87 In. Double Tank Rack Conveyor Dishwasher, Heat Recovery, Prewash, Dual Final Rinse","description":"\u003cp\u003eThe Blakeslee RC86 HR, sold by Blakeslee as the RC-86HR, is a double tank rack conveyor dishwasher with a prewash tank ahead of the 22.45 gal chemical wash tank and a two stage final rinse, rated for 240 to 340 racks of 20 x 20 in. dishware per hour. It adds an integrated heat recovery unit to the base machine and suits a hospital, university, or large hotel dishroom that wants to cut the cost of heating 137.4 gal of water per hour without giving up conveyor throughput. The heat recovery coil preheats incoming water with vapor that would otherwise go up the vent hood, so the machine is cold water input only: it runs on a 110 °F inlet configuration with the 28 kW booster and draws 69.18 kW total installed on three phase power. Throughput is set by the two speed conveyor and how quickly your crew racks, not by the machine alone, and the 86.5 in. body plus 12 in. load and unload ends calls for a straight run of at least 110.5 in. of dish table. Installation needs a three phase electrical supply, a 3\/4 in. cold water line at 30 to 87 psi, and a 1.57 in. centralized drain, with the legs adjusting the conveyor height between 35 and 37 in. to match your tables.\u003c\/p\u003e\u003ch3\u003ePrewash Tank, 22.45 Gal Chemical Wash Tank, and 240 to 340 Racks per Hour\u003c\/h3\u003e\u003cp\u003eRacks enter a dedicated prewash zone held at 115 °F, where a 1.9 kW pump knocks loose food off plates and trays before they reach the 22.45 gal chemical wash tank at 165 °F. Keeping the heavy soil in the prewash water means the wash tank stays cleaner longer, so your detergent keeps working through a full service instead of fighting gravy and starch that should have come off up front. The two speed traction conveyor runs the machine between 240 and 340 racks per hour and has a built-in clutch that lets the belt slip rather than jam if a rack catches, so a crooked tray rack does not stop the line. Dish and glass racks and tray baskets are 20 x 20 in., and the 19.25 x 7 in. cutlery basket rides through the same 17.5 in. passage height.\u003c\/p\u003e\u003ch3\u003ePre-Rinse and 180 °F Final Rinse With Built-In Booster\u003c\/h3\u003e\u003cp\u003eThe RC86 rinses twice. A 165 °F pre-rinse fed by a 0.2 kW pump and a 9 kW heating element flushes detergent off the ware, then the final rinse hits it at 180 °F for sanitizing. Because the heat recovery version takes cold water, the final rinse runs on the 28 kW booster that gives a 70 °F rise from a 110 °F supply, so you do not depend on a building hot water heater keeping up with 137.4 gal per hour. A pressure reducer stabilizes the final rinse at 15 to 25 psi flow pressure, which keeps rinse coverage even when another fixture opens on the same line. Water use is rated at 137.4 gal per hour, and the double rinse lets the machine reach that figure without a third tank.\u003c\/p\u003e\u003ch3\u003eSelf-Cleaning Vertical Wash Pump and Removable Surface Filters\u003c\/h3\u003e\u003cp\u003eEach tank is driven by a vertical, self-cleaning wash pump with overload protection, so a seized pump trips its protection instead of burning a motor. Stainless steel surface filters sit on top of every tank and lift out without detaching the wash arms, which means a dishwasher can clear a filter of lettuce and napkin shreds mid-shift in under a minute. The wash and rinse arms themselves are removable stainless steel, and the radial wash tank is sloped toward the 1.57 in. centralized drain so it empties fully at close instead of leaving a puddle of soil to dry overnight.\u003c\/p\u003e\u003ch3\u003eIntegrated Heat Recovery on Cold Water Input\u003c\/h3\u003e\u003cp\u003eThe heat recovery unit sits above the machine and runs the exhaust vapor across a coil that preheats incoming cold water before it reaches the tanks and booster. Blakeslee rates the savings at up to 20 percent over a machine without it, depending on your water temperature, hours of operation, and site conditions. Two things follow for the dishroom: the machine takes a single cold water connection and does not need hot water from the building, and it puts noticeably less steam into the room because that heat has been pulled back into the water. The electrical load reflects the setup, with 69.18 kW total installed and 197.5 A at 208 V, 187.3 A at 220-240 V, or 88.3 A at 480 V, three phase.\u003c\/p\u003e\u003ch3\u003eAISI 304 Structure With AISI 316 Tanks and Insulated Booster\u003c\/h3\u003e\u003cp\u003eThe frame and panels are AISI 304 stainless steel, and the tanks and booster are AISI 316, the grade used where detergent, chlorinated sanitizer, and hot water sit against the metal all day. The booster boiler is fully insulated to cut thermal loss between racks. The inspection door is an insulated double skin panel, counterbalanced so it stays where you leave it and fitted with an anti-drop safety system so it does not slam on a hand reaching into the wash chamber. The machine stands 74 in. tall with 84.4 in. needed to open the door, is 31.6 in. deep (34.5 in. with connections), and sits on legs adjustable from 5.9 to 7.8 in.\u003c\/p\u003e\u003ch3\u003eLow Voltage Soft Touch Controls With Rack-Detection Economizers\u003c\/h3\u003e\u003cp\u003eA low voltage electronic soft touch panel rated IPX5 runs the machine, so it shrugs off the hose-down at closing and gives your crew flat buttons with no knobs to break. Economizers in each zone run the pumps and rinse only when a rack is detected there, so gaps on the belt do not burn water, chemicals, or power. The auto timer shuts off the conveyor motor after the last rack passes, which saves the operator from remembering to hit stop between waves of bus tubs. A break tank fills the wash tanks and a vacuum breaker fills the booster, both there to prevent backflow into the building water supply.\u003c\/p\u003e","brand":"Blakeslee","offers":[{"title":"Default Title","offer_id":68155642708253,"sku":"RC86 HR","price":30257.63,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0699\/4716\/2909\/files\/90372_RC86_HR_flat.jpg?v=1795424647","url":"https:\/\/thechefstore.com\/products\/blakeslee-rc86-hr-87-in-double-tank-rack-conveyor-dishwasher-heat-recovery-prewash-dual-final-rinse","provider":"TheChefStore.Com","version":"1.0","type":"link"}