The Manitowoc UDP0310W Undercounter Cube Ice Machine
The Manitowoc UDP0310W is the water-cooled version of the largest dice-cube machine in the NEO undercounter ice machine line, built for hot, enclosed, or ventilation-limited spaces that still need modular-class production under the counter. It produces up to 300 lb of dice ice per 24 hours at 70°F air and 50°F water and holds 280 lb per day even in a 90°F kitchen, because the condenser rejects heat to the water line rather than fighting the ambient air, while the oversized 119 lb bin keeps enough reserve that back-to-back rushes do not empty it. The trade-off is honest: the condenser circuit uses 160 gal of water per 100 lb of ice, so the air-cooled sibling UDP0310A is the more economical choice where water is metered tightly and the room stays cool. Plan on a standard 115V outlet, separate ice-making and condenser water lines, and three drains; the 30 in. wide cabinet stands 38.5 in. tall overall on its 6 in. stainless steel legs.
Dice Cube Ice Maker and 119 lb Bin in One 30 In. Wide Cabinet
The cabinet measures 30 in. wide by 28.50 in. deep by 38.5 in. tall overall on its 6 in. adjustable stainless steel legs, pairing the ice maker and storage bin in one stainless steel enclosure instead of a coordinated head-and-bin stack. The storage bin is removable and slides forward, so a technician reaches the refrigeration components for cleaning and maintenance without pulling the cabinet out from under the counter. A plastic NEO ice scoop ships standard, and the dice cube measures 7/8 in. square, a shape that packs tight in glassware and melts slowly in beverage service.
Front Air Intake and Exhaust with No Minimum Clearance
The cabinet ventilates through the front, and Manitowoc requires no minimum clearance at the top, sides, or back, though 5 in. is recommended where the floor plan can spare it. Because this model sends condenser heat down the water line instead of out into the room, it suits tight enclosures and warm back-of-house corners where an air-cooled machine would recirculate its own exhaust. Operating limits run from 50°F to 100°F ambient with incoming water from 45°F to 90°F.
R290 Refrigerant System with a 0.5 HP Compressor on a 115V Circuit
A 0.5 HP compressor and R290 refrigerant system draw 7.0 amps on a 115/60/1 circuit with a factory-fitted 8 ft cord and NEMA 5-15P plug; 208-230/60/1 and 230/50/1 versions are available, with the 208-230V build shipping a cord only and no plug. The water-cooled condenser is cupra-nickel, a material choice that protects against corrosive water elements over years of service, and it accepts condenser inlet water from 20 to 150 psi. Expect 4.66 kWh and 15.5 gal of potable ice-making water per 100 lb of ice at the 90°F/70°F rating point, plus 160 gal of condenser water per 100 lb; the 15 amp maximum fuse size accepts HACR-type circuit breakers.
Up-Front Touchpad with Onboard Water Filtration
An easy-to-read touchpad on the front of the machine handles on and off, production delay, clean, filter change, full bin, and service indications, so staff see at a glance why the machine paused instead of calling for service on a full bin. The production delay can be set for 8 or 16 hours to slow output through overnight lulls. Water filtration is built onboard rather than plumbed as a separate housing, which improves machine efficiency and performance while keeping ice cleaner and clearer, and the filter change indicator tells you when the cartridge is due.
Features & Benefits
-
Built for hot, ventilation-limited spaces needing the largest NEO undercounter format
-
Rebuilds its bin reserve through the rush so staff keep scooping between orders
-
Fits under standard counters at 30 in. wide with front ventilation only
-
Installs against walls and equipment with no minimum clearance required by the manufacturer
-
Up-front touchpad with delay, clean, filter change, full bin, and service indicators
-
Onboard water filtration for cleaner, clearer ice and improved machine efficiency
-
Removable forward-sliding storage bin for easy access to refrigeration components during maintenance
-
Production delay settings of 8 or 16 hours for slower overnight demand
-
Water-cooled cupra-nickel condenser for protection from corrosive water elements over time
-
Dice cubes sized to pack tight in glassware and melt slowly in beverage service
-
Standard plastic NEO ice scoop included for serving straight from the bin
Free Shipping 48 Contiguous states & DC only.
In Stock: Ships in 1-2 Business Days
The Manitowoc UDP0310W Undercounter Cube Ice Machine
The Manitowoc UDP0310W is the water-cooled version of the largest dice-cube machine in the NEO undercounter ice machine line, built for hot, enclosed, or ventilation-limited spaces that still need modular-class production under the counter. It produces up to 300 lb of dice ice per 24 hours at 70°F air and 50°F water and holds 280 lb per day even in a 90°F kitchen, because the condenser rejects heat to the water line rather than fighting the ambient air, while the oversized 119 lb bin keeps enough reserve that back-to-back rushes do not empty it. The trade-off is honest: the condenser circuit uses 160 gal of water per 100 lb of ice, so the air-cooled sibling UDP0310A is the more economical choice where water is metered tightly and the room stays cool. Plan on a standard 115V outlet, separate ice-making and condenser water lines, and three drains; the 30 in. wide cabinet stands 38.5 in. tall overall on its 6 in. stainless steel legs.
Dice Cube Ice Maker and 119 lb Bin in One 30 In. Wide Cabinet
The cabinet measures 30 in. wide by 28.50 in. deep by 38.5 in. tall overall on its 6 in. adjustable stainless steel legs, pairing the ice maker and storage bin in one stainless steel enclosure instead of a coordinated head-and-bin stack. The storage bin is removable and slides forward, so a technician reaches the refrigeration components for cleaning and maintenance without pulling the cabinet out from under the counter. A plastic NEO ice scoop ships standard, and the dice cube measures 7/8 in. square, a shape that packs tight in glassware and melts slowly in beverage service.
Front Air Intake and Exhaust with No Minimum Clearance
The cabinet ventilates through the front, and Manitowoc requires no minimum clearance at the top, sides, or back, though 5 in. is recommended where the floor plan can spare it. Because this model sends condenser heat down the water line instead of out into the room, it suits tight enclosures and warm back-of-house corners where an air-cooled machine would recirculate its own exhaust. Operating limits run from 50°F to 100°F ambient with incoming water from 45°F to 90°F.
R290 Refrigerant System with a 0.5 HP Compressor on a 115V Circuit
A 0.5 HP compressor and R290 refrigerant system draw 7.0 amps on a 115/60/1 circuit with a factory-fitted 8 ft cord and NEMA 5-15P plug; 208-230/60/1 and 230/50/1 versions are available, with the 208-230V build shipping a cord only and no plug. The water-cooled condenser is cupra-nickel, a material choice that protects against corrosive water elements over years of service, and it accepts condenser inlet water from 20 to 150 psi. Expect 4.66 kWh and 15.5 gal of potable ice-making water per 100 lb of ice at the 90°F/70°F rating point, plus 160 gal of condenser water per 100 lb; the 15 amp maximum fuse size accepts HACR-type circuit breakers.
Up-Front Touchpad with Onboard Water Filtration
An easy-to-read touchpad on the front of the machine handles on and off, production delay, clean, filter change, full bin, and service indications, so staff see at a glance why the machine paused instead of calling for service on a full bin. The production delay can be set for 8 or 16 hours to slow output through overnight lulls. Water filtration is built onboard rather than plumbed as a separate housing, which improves machine efficiency and performance while keeping ice cleaner and clearer, and the filter change indicator tells you when the cartridge is due.
Features & Benefits
-
Built for hot, ventilation-limited spaces needing the largest NEO undercounter format
-
Rebuilds its bin reserve through the rush so staff keep scooping between orders
-
Fits under standard counters at 30 in. wide with front ventilation only
-
Installs against walls and equipment with no minimum clearance required by the manufacturer
-
Up-front touchpad with delay, clean, filter change, full bin, and service indicators
-
Onboard water filtration for cleaner, clearer ice and improved machine efficiency
-
Removable forward-sliding storage bin for easy access to refrigeration components during maintenance
-
Production delay settings of 8 or 16 hours for slower overnight demand
-
Water-cooled cupra-nickel condenser for protection from corrosive water elements over time
-
Dice cubes sized to pack tight in glassware and melt slowly in beverage service
-
Standard plastic NEO ice scoop included for serving straight from the bin
Resources & Downloads
Specifications
| Ice Production (70°F Air / 50°F Water) | 300 lb per 24 hours |
| Ice Production (90°F Air / 70°F Water) | 280 lb per 24 hours |
| Storage Bin Capacity | 119 lb |
| Ice Shape | Dice |
| Cube Size | 7/8 in. x 7/8 in. x 7/8 in. |
| Condenser Type | Water-cooled, self-contained, cupra-nickel |
| Width | 30 in. |
| Depth | 28.50 in. |
| Cabinet Height | 32.50 in. |
| Overall Height | 38.50 in. on legs |
| Cabinet Volume | 3.99 cu ft |
| Legs | 6 in., adjustable stainless steel |
| Exterior Finish | Stainless steel |
| Compressor | 0.5 HP nominal |
| Refrigerant | R290 |
| Heat Rejection | 5,500 BTU/hr average, 6,500 BTU/hr peak |
| Electrical | 115V, 60 Hz, 1 phase |
| Alternate Voltage | 208-230V/60/1 or 230V/50/1 |
| Total Ampacity | 7.0 amps (115V) |
| Maximum Fuse Size | 15 amps (HACR-type breakers acceptable) |
| Power Cord | 8 ft with NEMA 5-15P plug |
| Energy Usage | 4.66 kWh per 100 lb of ice at 90°F/70°F |
| Potable Water Usage | 15.5 gal per 100 lb of ice at 90°F/70°F |
| Condenser Water Usage | 160 gal per 100 lb of ice |
| Ice Making Water Inlet | 3/8 in. FPT |
| Ice Making Water Drain | 1/2 in. FPT |
| Bin Drain | 1/2 in. FPT |
| Condenser Water Inlet | 3/8 in. FPT |
| Condenser Water Drain | 1/2 in. FPT |
| Condenser Water Pressure | 20 psi minimum, 150 psi maximum |
| Water Pressure (Ice Maker) | 20 psi minimum, 80 psi maximum |
| Ambient Temperature Range | 50°F to 100°F |
| Water Temperature Range | 45°F to 90°F |
| Airflow | Front intake and exhaust |
| Clearance | None required; 5 in. recommended at top, sides, back |
| Production Delay | 8 or 16 hours, set from touchpad |
| Ice Scoop | Plastic scoop included |
Manufacturer's Warranty
-
5 Year
Compressor
-
5 Year
Evaporator
-
3 Year
Labor
-
3 Year
Parts
Certifications & Approvals
-
ETL Sanitation
-
ETL US & Canada