The Univex FA-73 Fat Percentage Measuring Kit
The Univex FA-73 manual fat analyzer gives you a quick, reliable way to measure ground beef fat content up to 90% lean. Built for butcher shops, grocery stores, and meat processors, this portable unit delivers accurate results in just three minutes. You can check product labels, maintain quality control, and meet regulations without sending samples to a lab. The FA-73 is made in the USA and comes ready to use with a carrying case and six glass vials.
Self-Calibrating Design Eliminates External Calibration Requirements
The FA-73 automatically calibrates itself to zero before each test, so you never need extra calibration tools or service visits. This self-calibrating design keeps results accurate and reduces maintenance. Tested against AOAC and Modified Babcock methods, the FA-73 delivers results within 1% accuracy for all types of ground beef, so you can trust your measurements every time.
Single Lever Manual Operation with 3-Minute Cycle Time
A single lever controls the FA-73, so anyone can use it without special training. Each test takes just three minutes, letting you check fat content quickly without slowing down production. The manual design means there are no air compressors or hydraulic systems to maintain, which keeps costs down and reduces the chance of breakdowns while still delivering precise results.
The compact analyzer measures just 5.5" wide by 5.4" deep by 5.6" high and weighs only 8 lbs., making it highly portable for use in multiple locations or for transport between facilities. The included carrying case protects the unit during storage and transport while keeping all components organized and accessible. Standard accessories include a sample measuring device for consistent portioning, the protective carrying case, and six glass vials to begin testing immediately upon arrival. Additional glass vials are available in cartons of 48 for ongoing operations.
About Univex
Since 1948, Univex has manufactured mixers, slicers, dough processors, pizza ovens, and prep equipment trusted in restaurants, pizzerias, bakeries, hotels, catering operations, and institutions. Known for rugged engineering that delivers decades of service, Univex balances durability with competitive pricing to provide strong long-term value. The company has also led the way in practical innovation, with operator-focused safety features that set industry standards. Backed by a reliable service and parts network, Univex continues to support commercial kitchens with equipment designed for demanding production environments.
Features & Benefits
-
Industry standard for measuring fat content of ground beef up to 90% lean (minimum fat content 10%)
-
Self-calibrating system sets machine to read zero with each measurement, no external calibration needed
-
Single lever manual operation requires no specialized training
-
Three-minute cycle time for rapid testing
-
Tested against AOAC method and Modified Babcock method with results within 1% accuracy
-
Compact design: 5.5" W x 5.4" D x 5.6" H
-
Lightweight at 8 lbs. for easy portability
-
Includes carrying case and six glass vials
-
Sample measuring device included for consistent portioning
-
Made in the USA
-
Carton of 48 glass vials available as optional accessory
Free Shipping 48 Contiguous states & DC only.
In Stock: Ships in 1-2 Business Days
The Univex FA-73 Fat Percentage Measuring Kit
The Univex FA-73 manual fat analyzer gives you a quick, reliable way to measure ground beef fat content up to 90% lean. Built for butcher shops, grocery stores, and meat processors, this portable unit delivers accurate results in just three minutes. You can check product labels, maintain quality control, and meet regulations without sending samples to a lab. The FA-73 is made in the USA and comes ready to use with a carrying case and six glass vials.
Self-Calibrating Design Eliminates External Calibration Requirements
The FA-73 automatically calibrates itself to zero before each test, so you never need extra calibration tools or service visits. This self-calibrating design keeps results accurate and reduces maintenance. Tested against AOAC and Modified Babcock methods, the FA-73 delivers results within 1% accuracy for all types of ground beef, so you can trust your measurements every time.
Single Lever Manual Operation with 3-Minute Cycle Time
A single lever controls the FA-73, so anyone can use it without special training. Each test takes just three minutes, letting you check fat content quickly without slowing down production. The manual design means there are no air compressors or hydraulic systems to maintain, which keeps costs down and reduces the chance of breakdowns while still delivering precise results.
The compact analyzer measures just 5.5" wide by 5.4" deep by 5.6" high and weighs only 8 lbs., making it highly portable for use in multiple locations or for transport between facilities. The included carrying case protects the unit during storage and transport while keeping all components organized and accessible. Standard accessories include a sample measuring device for consistent portioning, the protective carrying case, and six glass vials to begin testing immediately upon arrival. Additional glass vials are available in cartons of 48 for ongoing operations.
About Univex
Since 1948, Univex has manufactured mixers, slicers, dough processors, pizza ovens, and prep equipment trusted in restaurants, pizzerias, bakeries, hotels, catering operations, and institutions. Known for rugged engineering that delivers decades of service, Univex balances durability with competitive pricing to provide strong long-term value. The company has also led the way in practical innovation, with operator-focused safety features that set industry standards. Backed by a reliable service and parts network, Univex continues to support commercial kitchens with equipment designed for demanding production environments.
Features & Benefits
-
Industry standard for measuring fat content of ground beef up to 90% lean (minimum fat content 10%)
-
Self-calibrating system sets machine to read zero with each measurement, no external calibration needed
-
Single lever manual operation requires no specialized training
-
Three-minute cycle time for rapid testing
-
Tested against AOAC method and Modified Babcock method with results within 1% accuracy
-
Compact design: 5.5" W x 5.4" D x 5.6" H
-
Lightweight at 8 lbs. for easy portability
-
Includes carrying case and six glass vials
-
Sample measuring device included for consistent portioning
-
Made in the USA
-
Carton of 48 glass vials available as optional accessory
Resources & Downloads
See all from Univex
Specifications
| Measurement Range | Up to 90% lean (minimum 10% fat content) |
| Cycle Time | 3 minutes |
| Operation | Single lever manual |
| Calibration | Self-calibrating, no external calibration required |
| Accuracy | Within 1% when tested against AOAC and Modified Babcock methods |
| Width | 5.5" (140 mm) |
| Depth | 5.4" (137 mm) |
| Height | 5.6" (142 mm) |
| Net Weight | 8 lbs. (3.6 kg) |
| Shipping Weight | 10 lbs. (4.5 kg) |
| Shipping Dimensions | 12" H x 12" W x 12" D (30.5 cm x 30.5 cm x 30.5 cm) |
| Standard Voltage | 115V, 60 Hz, 1-phase |
| Optional Voltage | 220V, 60 Hz, 1-phase |
| Motor Power | 1.00 HP (0.75 kW) |
| Amperage (115V) | 0.9 Amps |
| Amperage (220V) | 0.4 Amps |
| Plug Type | NEMA 5-15P |
| Standard Accessories | Sample measuring device, carrying case, six glass vials |
| Optional Accessories | Carton of 48 glass vials |
| Country of Manufacture | Made in the USA |
Certifications & Approvals
-
ETL US & Canada
-
ETL Sanitation
-
Made in USA